Galaxy 2000 Bariatric Alternating Air Profiling Replacement Mattress
  Zoom
Galaxy 2000 Bariatric Alternating Air Profiling Replacement MattressGalaxy 2000 Bariatric Alternating Air Profiling Replacement MattressGalaxy 2000 Bariatric Alternating Air Profiling Replacement MattressGalaxy 2000 Bariatric Alternating Air Profiling Replacement Mattress
Free UK Delivery On All OrdersSpeak to Our Product Experts for More Advice

Galaxy 2000 Bariatric Alternating Air Profiling Replacement Mattress

  • Available in 4 sizes;
  • Foam base layer;
  • Built in hip & knee area hinges;
  • Adjustable to patient’s weight.
Size:  
£2,235.99(Inc. 20% VAT)
(£1,863.33 Exc. VAT)

Galaxy 2000 Bariatric Alternating Air Profiling Replacement Mattress

The Galaxy 2000 Bariatric Alternating Air Profiling Replacement Mattress is designed for the rough and tumble of nursing home and hospital usage. It has been designed with reliability as a paramount importance, the Galaxy 2000 system has no elaborate or unnecessary electronics that can increase the chances of electricity spikes, make systems more difficult to operate, or expensive to service or replace.

The Galaxy 2000 Bariatric Alternating Air Profiling Replacement Mattress can be inclined to 60 degrees with minimal or no cell compression. Such an incline is made possible with Turnaido 2000’s technologically advanced design, which combines a unique hinging mechanism, and circular cells that cannot topple, that work together to prevent air cells from falling like dominoes and squashing when the mattress is profiled beyond 40 degrees.

The Galaxy 2000 Bariatric Alternating Air Profiling Replacement Mattress provides effective pressure relief whilst helping to keep patients safe and comfortable. A patient slipping down the bed can lead to compression of the diaphragm, and increased lower back strain and for the carer, it can increase the need for the patient to be lifted back up the bed, which contravenes the Minimum Lifting Policy. The Galaxy 2000 Bariatric Alternating Air Profiling Replacement Mattress helps with these situations as it can be used with profiling beds.

Features of the Galaxy 2000 Bariatric Alternating Air Profiling Replacement Mattress

  • Designed to harmonize with a new generation of profiling beds recommended by N.C.S.C. (Standard 24.3).
  • A built in hip and knee area hinges to ensure that Galaxy 2000’s “point of articulation” is closer to the level of the spine and legs, than with full depth air mattresses which gives more effective pressure relief when sitting up in bed.
  • A foam under layer provides security against mains electricity blackouts and incorrect pressure settings being set, by preventing the patient from bottoming out on to the hard bed-frame base. This under layer also provides stability when manoeuvring or getting out of bed.
  • Adjustable to patient’s weight for optimum pressure relief.
  • Waterproof, vapour permeable two way stretch covers that are loose fitting to avoid unnecessary tension or hammocking, which could force the cover out of shape.
  • Sealed top surface seams and full depth side flaps minimise the risk of liquid ingress.
  • Power unit is both energy efficient and quiet in operation with lightweight and compact construction.
  • Two adjustable girth straps fasten the mattress securely to the bed frame.
  • Wide versions ideally suited for bariatric patients

Benefits of the Galaxy 2000 Bariatric Alternating Air Profiling Replacement Mattress for Patients and Carers

  • Two ways stretch covers are waterproof/vapour permeable for optimum patient comfort and care.
  • Offers a 60 degree incline with minimal or no cell compression, allowing patients to sit up comfortably whilst reading, eating, watching television, with minimal shear.
  • Can be set to stay inflated for approximately 24 hours, if a mains power failure should occur.
  • Patients do not slip down the bed, and therefore it can save nursing time from not having to repeatedly reposition patients back up the bed.

Specifications of the Galaxy 2000 Bariatric Alternating Air Profiling Replacement Mattress

Pump

Dimensions

305 x 145 x 100 mm

Weight

1.8kg

Rated Voltage

220/240V

Cycle Time

15 minutes

Alteration Cycle

ABAB

Electricity Safety Standard

BS 5742, Part 1;IEC 601-1; EN 60601-1 

Mattress and Cover

Dimensions

2040 x 860/1070/1223 x 205mm

Inflated Cell Height

115mm

Pressure Relieving Foam Base

2040 x 860 x 90mm

Product Weight

20kg

British Standard Compliance

BS6807; BS7175; BS3424/37